EQUIVALENT STANDARDS | Temper | 0.2% Proof Stress Mpa Min. | Ultimate Tensile Strength Mpa Min. | Elongation % on 50mm Gauge % Min. | Typical Brinell Hardness No BHN | ||||||
INDIA | U.S.A. | BRITAIN | Old | New | |||||||
E I | F | --- | (65) | (18) | 20 | ||||||
19500 | 1050 | E I B | M | F | --- | (65) | (23) | ||||
H9 | M W P WP |
F T4 T5 T6 |
--- 80 140 150 |
(110) 140 170 185 | (13) 14 7 7 |
--- 45 --- 60 |
|||||
E 91 E | W WP |
T4 T6 |
80 135 | 140 170 | 12 1 2 |
--- |
|||||
64430 | 6351 | H 30 | M W WP |
F T4 T6 |
--- 120 270 |
(110) 185 310 | (14) 14 7 |
--- 60 95 |
|||
6251 | H 20 | M W WP |
F T4 T6 |
--- 115 |
(110) 185 280 | (12) 14 7 |
--- 55 85 |
||||
--- | 8 | 80 | |||||||||
--- | 6060 | --- | T4 T5 T6 |
60 100 150 |
120 145 190 | 16 8 8 |
--- --- 60 |
||||
--- | --- | T4 T6 T6510 |
115 --- 240 |
190 --- 280 |
16 --- 8 |
6 --- 85 |
|||||
Note : No Mechanical Properties are specified in F ( or M) Condition
The bracketed values are given for information only.
1 Mpa = 1 N / mm2 = 0.102 kgf / mm2
Typical BHN values are given for information only and no guarantee is implied.